Default Run Time Display | |
Phase 2 Programming Display | |
Diagnostic Selection Display | |
Switch Diagnostic Display | |
Memory Diagnostic Display | |
Operator Keypad |
Default Run Time Display |
Display | Name | Range of Values |
TF | TOTAL FEED | +9.9999 to -9.9999 inches |
TD | TOTAL DEPTH | 0.0000 to 9.9999 inches |
DTS | DEPTH TO SPARKOUT | .0000 to .0099 inches |
NS | NUMBER OF SPARKOUTS | 00 to 99 sparkouts |
FL | FEED LEFT | .0000 to .0099 inches |
FR | FEED RIGHT | .0000 to .0099 inches |
RA | RAPID ADVANCE | 0.0000 to 9.9999 inches |
IDLE | STATE | IDLE, START, INTERRUPT, RETURN |
NRET | RETURN MODE | NRET=NON-RETURN; RET=RETURN |
PL | TABLE MODE | CF=CROSS FEED; PL=PLUNGE |
|
|
|
|
|
Number keys | 0-9 |
EXIT/PROG | Exit cycle after pressing interrupt |
F1 - F4 | Special Function keys (F1 = Diagnostics) |
Arrow Keys | Move display cursor in arrow direction |
ENTER | Special Function enter key |
JOG UP | Move UP 0.0001 inch |
JOG DOWN | Move DOWN 0.0001 inch |
RAPID UP | Move UP rapidly |
RAPID DOWN | Move DOWN rapidly |
RETURN | Program to return HOME at the end of the cycle |
NON-RETURN | Program to remain in position at the end of the cycle until RETURN is pressed |
INTERRUPT | Stop a cycle for reprogramming or termination |
START/RESTART | Start a new cycle or restart an interrupted cycle |