Step Control User's Manual
 
             Default Run Time Display
             Phase 2 Programming Display
             Diagnostic Selection Display
             Switch Diagnostic Display
             Memory Diagnostic Display
             Operator Keypad

 
Default Run Time Display
Display Name Range of Values
TF TOTAL FEED +9.9999 to -9.9999 inches
TD TOTAL DEPTH 0.0000 to 9.9999 inches
DTS DEPTH TO SPARKOUT .0000 to .0099 inches
NS NUMBER OF SPARKOUTS 00 to 99 sparkouts
FL FEED LEFT .0000 to .0099 inches
FR FEED RIGHT .0000 to .0099 inches
RA RAPID ADVANCE 0.0000 to 9.9999 inches
IDLE STATE IDLE, START, INTERRUPT, RETURN
NRET RETURN MODE NRET=NON-RETURN; RET=RETURN
PL TABLE MODE CF=CROSS FEED; PL=PLUNGE
 

 
Phase 2 Programming Display
PHASE 2           FL     .0001
D2    0.0000       FR    .0001
DTS   .0010       PRESS EXIT
NS   10               OR START

 
Diagnostic Selection Display
SELECT MODE OR EXIT
1    SWITCHES
2    MEMORY
3    DEFAULTS


 
Switch Diagnostic Display
CF   1    PL   1
TF   0    TL   1
TR   1    TR   1
KEY   00

 
Memory Diagnostic Display

Ext. Address 07ff:
00, 00, 00, 00, 00, 00, 00
00, 00, 00, 00, 00, 00, 00
00, 00, 00, 00, 00, 00, 00

 
Operator Keypad
1 2 3 F1 F2 JOG
UP
JOG
DOWN
4 5 6 F3 F4 RAPID
UP
RAPID
DOWN
7 8 9 ENTER RETURN NON-
RETURN
EXIT/
PROG
0 INTER-
RUPT
START/
RESTART
Number keys 0-9
EXIT/PROG Exit cycle after pressing interrupt
F1 - F4 Special Function keys (F1 = Diagnostics)
Arrow Keys Move display cursor in arrow direction
ENTER Special Function enter key
JOG UP Move UP 0.0001 inch
JOG DOWN Move DOWN 0.0001 inch
RAPID UP Move UP rapidly
RAPID DOWN Move DOWN rapidly
RETURN Program to return HOME at the end of the cycle
NON-RETURN Program to remain in position at the end of the cycle until RETURN is pressed
INTERRUPT Stop a cycle for reprogramming or termination
START/RESTART Start a new cycle or restart an interrupted cycle